Generator Security Operating Regulations

For a generator powered by a diesel engine, the procedure of the engine component will be executed in accordance with the appropriate laws of the inner combustion engine.

1

1. For a generator powered by a diesel engine, the procedure of the engine component will be executed in accordance with the appropriate laws of the inner combustion engine.
2. Prior to starting the generator, you have to thoroughly inspect whether the wiring of each part is proper, whether the attaching parts are trusted, whether the brush is normal, whether the stress fulfills the requirements, as well as whether the basing cord is good.
3. Before beginning, put the resistance value of the excitation rheostat in a bigger setting, separate the result switch, as well as the generator established with the clutch must disengage the clutch. Beginning the diesel motor without any lots initially, and afterwards start the generator after running efficiently.
4. After the generator begins to run, you should always take notice of whether there is any type of mechanical noise, abnormal vibration, etc. After verifying that the situation is regular, change the generator to the ranked speed, readjust the voltage to the rated worth, and after that shut the outcome switch to supply power. The tons ought to be progressively raised to pursue three-phase balance.
5. The parallel procedure of generators have to fulfill the conditions of the same regularity, the very same voltage, the very same stage, and the same phase sequence.
6. The generators to be run in parallel should have gotten in regular as well as stable operation.

 2

7. After obtaining the signal of “preparing for parallel link”, adjust the speed of the diesel motor according to the whole tool, and shut the button right now of synchronization.
8. The generators running in parallel should change the load reasonably, and equally disperse the active power and reactive power of each generator. Energetic power is managed by the diesel throttle, and responsive power is regulated by excitation.
9. The running generator must pay close attention to the noise of the engine and observe whether the indicators of numerous tools are within the regular variety. Inspect whether the running component is normal and also whether the temperature level increase of the generator is too expensive. and maintain a running record.
10. When stopping, initial reduce the lots, bring back the excitation rheostat to reduce the voltage to a smaller value, after that cut off the switches in turn, as well as lastly stop the diesel motor running.
11. If a diesel engine running in identical needs to be stopped as a result of a drop in lots, the load of a generator that requires to be stopped should be transferred to the generator that continues to run, and after that the quit is done according to the approach of quiting a single generator. If all quits are required, the tons will certainly be cut off initially, and after that the single generator will be quit.
12. For mobile generators (mobile power stations), the chassis has to be parked on a stable structure before usage, as well as it is not allowed to move throughout procedure.
13. When the generator is running, even if no excitation is added, it needs to be taken into consideration to have voltage. It is forbidden to service the lead cord of the rotating generator and touch the blades or clean it by hand. The running generator shall not be covered with canvas etc 14. After the generator is overhauled, it is essential to meticulously check whether there are devices, materials and also other particles between the rotor and also stator slots to stay clear of damage to the generator during procedure.
15. All electrical tools in the computer room should be based reliably.
16. It is forbidden to pile up sundries as well as combustible as well as eruptive materials in the computer system room. Except for the workers at work, other personnel are banned from going into without permission.
17. Required fire-fighting tools must be mounted in the space. In case of a fire accident, the power transmission need to be stopped quickly, the generator must be turned off, and a co2 or carbon tetrachloride fire extinguisher need to be utilized to produce the fire.