How to run the diesel generator set safely?

( 1) Automatic state
1. The battery pack that maintains the electric motor is kept at the beginning voltage.
2. Keep the cooling water degree of the radiator usually, and the distributing water valve is frequently opened up.
3. The gas level of the crankshaft box is maintained in the series of ± 2cm of the oil ruler.
4. The fuel storage tank oil is majority, and also the gas supply valve is usually opened up.
5. The “procedure -stop -automatic” switch of the generator control screen is positioned in the “automatic” setting.
6. The mode button of the power circulation screen remains in the “automatic” setting.
7. The radiator fan switch is struck in the “automatic” setting.
8. After getting the signal of the local power loss, the system was begun to confirm the community power loss, reduced the conversion cabinet’s electrical button, shut the conversion cabinet power generation switch, and also start the air inlet and exhaust denses of the computer space.

syred (1)

( 2) By hand begin
1. When the indoor temperature is lower than 20 ° C, switch on the electric heating system and preheat the device.
2. Inspect that the body and also surrounding are not impeded to run.
3. Examine the gas level, gas container oil degree, as well as radiator water level. If the water degree is lower than the specified value, it needs to be added to the normal placement.
4. Examine whether the gas supply valve and the cooling water reducing shutoff remain in the opening setting.
5. Check whether the battery package voltage of the electric battery pack is regular.
6. Evaluate the test button of the power circulation display to observe whether the alarm indication lights are switched on.
7. Examine whether each turn on the power distribution screen is placed in the split position, as well as each instrument suggests whether it is zero.
8. Start the air inlet and also exhaust.
9. Press the starting switch of the engine to start procedure. If the initial start falls short, you can press the matching reset switch on the power distribution display to be gotten rid of by the alarm system and also the system response to the regular state prior to the 2nd start. After starting, the maker’s running sound is typical, the cooling water pump running sign lights and also the roadway instrument indicator is regular, and also the startup is successful.
( 3) Hand-operated procedure identical power supply
1. The oil temperature, water temperature level, and also oil stress of the electric motor to send the motor reaches normal worths, and operate typically.
2. The value of the outcome voltage and regularity of the measuring motor follows the worth on the parent.
3. Hit the synchronizer handle of the identical generator set at the “closure” position.
4. Observe the sign light and reminder of the simultaneous sign.
5. Observe the sign light of the synchronous indicator. When it is entirely snuffed out or turns to absolutely no, the identical switch can be done.
6. The system goes into the side of the auto and also runs back, and then the synchronizer manage is revolved back to the “off” placement.
7. If the synchronizer turns as well rapid or rotates at the back timing after the synchronizer is closed, the vehicle is not allowed, otherwise, it will cause the closing to fall short.
8. After the manual side succeeds, you ought to right away get in touch with the low -voltage power circulation room to apply whether the total power distribution screen can be used to send out the electricity to the power and afterwards run.

syred (2)

( 4) Operating safety management
1. Check the tools of each indicator based on the proposed time. Take notice of the pressure of lubricating oil and whether the water temperature level adjustments. The pressure of lubricating oil must not be less than 150kPa, and the temperature level of the cooling water should not be more than 95 ° C.
2. Examine the gas level, fuel container oil level, and also radiator water degree, as well as ought to be supplemented by normal placements.
3. Whether each tool and also alarm indication of the power circulation screen is typical. All red lights are damaged, and the green light is running generally.
4. Inspect whether the battery charger is charged normally.
5. Listening to the audio of each part of the maker is normal.
6. Hand -molded body real estate, bearing shell, oil pipe, water pipe, whether the temperature level is normal.
7. Take note of whether there is a smell such as the coordination or the electrical tools.
8. If there are bad situations, it must be dealt with quickly; serious quit handling need to be stopped.
9. If the failing is stopped, the failure needs to be removed, and after that the staff can be operated according to the duplicated handle in the motivation team.
10. For every running parameters, each class documents less than two times.
( 5) Car Park
1. The result feed switch of the general control display is split into the power grid.
2. Park after 10 minutes of air loading of the generator.
3. Stop the fans, cooling water pumps, etc. of the computer system area.